Tankless Water Heater Size Calculator (Free Tool, 2026)
A tankless water heater that is too small gives you lukewarm showers the moment someone starts the dishwasher. This free calculator adds up your peak hot water flow (GPM) and your temperature rise, then shows the gas BTU or electric kW you need.
Add up the hot water you use at the same time to find the flow rate (GPM) and the gas BTU or electric kW your tankless heater needs.
Estimates only. Flow rates are typical low-flow fixture values. Always check the maker’s flow chart and have a licensed plumber or electrician confirm gas line, venting and breaker sizes.
How to Use the Tankless Water Heater Calculator
- Enter how many of each fixture could run at the same time on your busiest morning.
- Pick your region, or type the incoming water temperature if you know it.
- Set your hot water temperature. 120°F is the common recommendation.
- Choose gas or electric to see BTU or kW and amps.
How the Calculation Works
Heating water takes about 500 BTU per hour for every 1 GPM of flow and every 1°F of temperature rise. So the formula is:
BTU/h output = 500 × GPM × temperature rise
For gas, the calculator divides by 0.93 to account for a modern condensing unit’s efficiency. For electric, it divides by 3,412 to convert BTU/h to kW, and then shows the current draw at 240 volts.
Example: one shower and one kitchen sink (3.5 GPM) with 52°F incoming water and 120°F hot water is a 68°F rise. 500 × 3.5 × 68 = 119,000 BTU/h output, or about 128,000 BTU gas input, or 35 kW electric.
Typical Fixture Flow Rates
| Fixture | Typical flow rate |
|---|---|
| Low-flow shower head | 1.8–2.0 GPM |
| Standard shower head (federal max) | 2.5 GPM |
| Bathroom sink | 1.0–1.5 GPM |
| Kitchen sink | 1.5–2.2 GPM |
| Dishwasher | 1.0–1.5 GPM |
| Washing machine | 1.5–2.0 GPM |
| Bathtub | 4.0 GPM |
Tips Before You Buy
- Read the flow chart, not just the max GPM. A heater rated 9 GPM may deliver only 5 GPM at a 70°F rise.
- Plan for winter. Incoming water is coldest in January, so size for that month.
- Check your gas line and venting. Large gas units often need a bigger gas line and stainless or PVC venting.
- Check your electrical panel. Whole-house electric units can need 120 to 150 amps.
- Wi-Fi models let you track usage and set temperatures from your phone.
Frequently Asked Questions
What size tankless water heater do I need for a family of 4?
A family of four usually needs to run two showers, or one shower and a kitchen sink, at the same time. That is about 3.5 to 4 GPM. In the middle of the US, with a 68°F rise, a gas unit of roughly 150,000 to 199,000 BTU handles that. A 36 kW electric unit covers only about 3.5 GPM at that rise, so electric works best in warmer areas.
How do I calculate the GPM I need?
Add the flow rates of every fixture you might use at the same time. A low-flow shower uses about 2.0 GPM, a kitchen sink about 1.5 GPM and a bathroom sink about 1.0 GPM. Two showers and a kitchen sink add up to 5.5 GPM.
What is temperature rise?
Temperature rise is how much the heater has to warm the incoming water. If the ground water is 50°F and you want 120°F at the tap, the rise is 70°F. Colder climates need a bigger heater for the same flow rate.
Is gas or electric tankless better?
Gas units deliver much higher flow rates and work better in cold climates. Electric units are cheaper to install when you do not have gas, need no venting and are very efficient, but large models need a lot of amperage.
Can a tankless water heater run out of hot water?
It does not run out the way a tank does, but if you open more fixtures than it can heat, the water gets cooler. Sizing for your real peak use prevents this.