Home Battery Backup Calculator (Free Tool, 2026)

How big of a battery do you need for your house? This free home battery backup calculator sizes your battery in kWh from the appliances you want to keep running and how long the outage lasts. It also shows how many Tesla Powerwall, EcoFlow, FranklinWH or Enphase units that equals, with or without solar.

๐Ÿ”‹

Home Battery Backup Size Calculator

Pick what must stay on during an outage. We’ll size the battery in kWh and units.

Quick start
Appliances to back up
Backup time
Custom: 12 hours
Battery you need
0 kWh usable
Energy used in outage0 kWh
Average load0 W
Peak running power0 W
Startup surge0 W
How many units that means

Estimates use typical wattages and duty cycles plus ~15% for inverter losses and a safety reserve. Battery specs are manufacturer ratings (approx.); confirm with your installer, and use a licensed electrician for any home backup install.

Embed This Home Battery Backup Calculator on Your Site

Run a home improvement, smart home, contractor or real estate site? Add this free tool to any page. Copy the code below and paste it into an HTML block. It’s free, mobile-friendly and updates automatically.

Please keep the credit link below the tool. WordPress users: add a “Custom HTML” block and paste the code.

How to Use the Home Battery Backup Calculator

  1. Pick a quick start (Essentials, Essentials + AC or Most of the home), or clear it and build your own list.
  2. Add appliances with the + and โˆ’ buttons. Use the count for things you have more than one of, like ceiling fans.
  3. Choose how long the backup should last. 12 hours covers most outages; 48 to 72 hours suits storm and wildfire areas.
  4. Tick the solar box if you have panels. Enter the system size and your peak sun hours to see how much smaller the battery can be.
  5. Read the result: usable kWh you need, peak power, startup surge and how many units of popular batteries that equals.

How Battery Backup Size Is Calculated

The math is simple: battery size (kWh) = average load (watts) ร— hours of backup รท 1,000. We then add about 15% to cover inverter losses and a small reserve, so the battery doesn’t run flat.

The tricky part is the average load. A fridge is rated around 150 watts, but its compressor cycles on and off, so it averages closer to 60 watts over a day. The calculator uses these real-world averages instead of nameplate watts, which is why the result is usually smaller than a simple “add up the watts” estimate.

Energy is only half of the job. The battery also needs enough continuous power to run everything at once, and enough surge power to start motors like AC compressors, well pumps and sump pumps. That’s why the unit count looks at both kWh and kW.

Typical Appliance Power Draw

ApplianceRunning wattsAverage over a dayStartup surge
Refrigerator150 W~60 W (1.5 kWh/day)~1,200 W
Wi-Fi router + modem20 W20 Wโ€”
Security cameras + NVR60 W60 Wโ€”
Gas furnace blower600 W~300 W~1,200 W
Window AC (8,000 BTU)700 W~420 W~1,800 W
Central AC (3 ton)3,500 W~1,750 W~7,000 W
Well pump1,000 W~100 W~3,000 W

Want exact running costs for each appliance? Try our Appliance Energy Cost Calculator.

BatteryUsable capacityContinuous powerGood for
Tesla Powerwall 313.5 kWh11.5 kWWhole-home backup with solar (built-in solar inverter)
EcoFlow DELTA Pro Ultra~6 kWh per battery pack, expandable7.2 kWFlexible, partly portable backup that grows over time
FranklinWH aPower 215 kWh10 kWWhole-home backup with new or existing solar
Enphase IQ Battery 5P5 kWh3.84 kWModular systems paired with Enphase microinverters

Specs are approximate manufacturer ratings. Check the Tesla Powerwall and EcoFlow sites for current models and pricing.

Tips to Get the Right Size (and Spend Less)

  • Back up a critical loads panel instead of the whole house. Moving the fridge, lights, internet and a few outlets onto one sub-panel can halve the battery you need.
  • Add a soft starter to your AC. It cuts the compressor’s startup surge, which is often what forces people to buy a second battery.
  • Pair the battery with solar. Even a modest array can refill a battery during the day in a long outage. Size the panels with our Solar Panel Calculator.
  • Compare with a generator for long outages. Our Generator Size Calculator shows what a gas or propane unit would need to be.
  • Going portable? Check how long a smaller unit lasts with the Power Station Runtime Calculator.

For outage basics, see the U.S. Department of Energy’s Energy Saver guides. Always have a licensed electrician install home battery systems and transfer switches.

Frequently Asked Questions

How big of a battery do I need to run my house?

Most homes need 10 to 15 kWh to keep essentials like the fridge, lights, Wi-Fi and a few outlets running for a day. Backing up central AC or electric heating usually pushes that to 25 to 40 kWh or more. Use the calculator above with your own appliances for a closer number.

How long will a 13.5 kWh Powerwall run a house?

It depends on the load. At an average draw of 500 watts (fridge, lights, router, TV), 13.5 kWh lasts roughly 24 hours. At 1,500 watts with AC cycling, it lasts closer to 8 or 9 hours.

Can a home battery run central air conditioning?

Yes, if the battery’s continuous power and surge rating are high enough. A 3-ton AC can draw 3,500 watts while running and much more at startup. A soft-start kit and a battery with high surge capacity, or two batteries, usually make it work.

Is it better to get a battery or a generator?

A battery is silent, needs no fuel and switches over instantly, and with solar it can recharge every day. A generator is cheaper per kWh for long, multi-day outages. Many homes in storm areas pair a small battery with a portable generator.

Do I need solar to use a home battery?

No. A battery can charge from the grid and sit ready for outages. Solar lets it recharge during a long outage, so you can get by with a smaller battery.

What does usable capacity mean?